DMM-0200 Product User Guide
159 Swanson Road
Boxborough, MA 01719
Tel: 508-475-3400
Email: sales@dovermotion.com
JOGX+ ;***Jogs X axis to positive direction
DELAY= 1000 ;***Wait 1 second
SSPDMX=1 ;***Set on-the-fly speed change mode to 1
ACCX=20000 ;***Set acceleration to 20 seconds
SSPDX=190000 ;***Change speed on X-axis on-the-fly to 190000 PPS
STOP
Description:
Command: Stop all axes if in motion with deceleration. Previous acceleration value is used for deceleration.
Syntax:
STOP
Examples:
JOGX+ ;***Jogs X axis to positive direction
DELAY= 1000 ;***Wait 1 second
STOP ;***Stop with deceleration all axes including X axis
STOP[axis]
Description:
Stop individual axis if in motion with deceleration.
Previous acceleration value is used for deceleration.
Syntax:
STOP[axis]
Examples:
JOGX+ ;***Jogs X axis to positive direction
DELAY=1000 ;***Wait 1 second
JOGY+ ;***Jogs Y axis to positive direction
DELAY= 1000 ;***Wait 1 second
STOPX ;***Stop with deceleration X axis only
STORE
Description:
Store the device settings and the second half of variables (V32-V63) to flash
Syntax:
STORE
Examples:
V32=100
V33=200
STORE ;***Values of V1 and V2 will now be preserved after power cycle
SUB
Description:
Indicates start of subroutine
Syntax:
SUB [subroutine number]
[Subroutine Number] range is 0 to 31
Note: Subroutine 31 is reserved for error handling