DMM-0200 Product User Guide
159 Swanson Road
Boxborough, MA 01719
Tel: 508-475-3400
Email: sales@dovermotion.com
Programming Language Specification
;
Description:
Comment notation. In programming, comment must be in its own line.
Syntax:
; [Comment Text]
Examples:
; ***This is a comment
JOGX+ ;***Jogs X axis to positive direction
DELAY= 1000 ;***Wait 1 second
ABORT ;***Stop immediately all axes including X axis
ABORT
Description:
Motion: Immediately stops all axes if in motion without deceleration.
Syntax:
ABORT
Examples:
JOGX+ ;***Jogs X axis to positive direction
DELAY= 1000 ;***Wait 1 second
ABORT ;***Stop immediately all axes including X axis
ABORT[axis]
Description:
Motion: Immediately stops individual axis without deceleration.
Syntax:
ABORT[axis]
Examples:
JOGX+ ;***Jogs X axis to positive direction
JOGY+ ;***Jogs Y axis to positive direction
ABORTX ;***Stop the X-axis immediately
ABS
Description:
Motion: Changes all move commands to absolute mode.
Syntax:
ABS
Examples:
ABS ;***Change to absolute mode
PX=0 ;***Change X position to 0
X1000 ;***Move X axis to position 1000
WAITX
X2000 ;***Move X axis to position 2000
WAITX
ABORT ;***Stop immediately all axis including X axis