Returned error code
Meaning
1 Invalid command for object ID
2 Invalid Query/Command
3 Missing parameter
4 Parameter out of range
5
Invalid command in current state - e.g. serial com-
mand to s
tart/stop when in parallel control mode
11.2 Flashing service codes
Whenever a service is required the standard once per revoluon ash on the yellow
status LED is replaced with a service ash code.
Table 27
Flashing service codes
Service ash
code
Comments Acons
LED on 3sec
LED o 1sec
Bearing service recom-
mended
It is recommended that the bearing is re-
placed. Refer to Bearing maintenance on
page 89.
LED on 3sec
LED o 3sec
Pump service required
The turbo impeller or controller has
reached its expected life. It is recommen-
ded that the pump is returned to our serv-
ice centre for service. Refer to Bearing
maintenance on page 89.
11.3 Flashing error codes
Whenever a fail condion becomes acve, the red alarm lights connuously or shows a
ashing sequence.
If the error light is on connuously, this indicates a problem with the embedded
soware. In this case, try cycling the power. If cycling the power does not clear the
indiwill be required. Contact the supplier or Edwards. If the alarm LED is ashing,
idenfy the error ash code and consult the table in Decoding system status words on
page 102.
There is a sucient o period between each subsequent cycle repeon to clearly mark
the start of a new ash sequence. The duraon of a long ash (L) is equal to 3 mes the
duraon of a short ash (0.5 s).
Table 28
Flashing error codes
Error ash
posion
Error ash
code
Comments Acons
0 ssssss
The speed fell below 50% of full
rotaonal speed with the Timer
disabled.
Check whether the pump is too
hot or whether the inlet pressure
is too high.