Table 33
Service tool kits
Service tool kit
Item number
Bearing exchange tool kit nEXT730D/930D B8J200845
Bearing exchange tool kit nEXT1230H B8M200845
Table 34
Service kits
Service kit
Item number
Bearing kit nEXT730D/930D B8J200827
Bearing kit nEXT1230H B8M200827
12.4 Bearing run in mode
Bearing run in mode (BRIM) is a start-up sequence for the pump designed to
precondion the bearing to opmise bearing life. The pump goes through a number of
speed steps before reaching full speed.
The BRIM process last around 4.3 hours and the LED indicates when this is running.
BRIM mode can be cancelled by sending a stop signal and then start signal to a pump
currently running the BRIM process. This is NOT recommended and may invalidate
the warranty.
BRIM mode is either triggered:
▪ automacally by the pump
▪ manually thr
ough nST2
▪ manually through the TIC, or
▪ by pressing both speed adjustment push buons (located behind the service
cover) simultaneously for 2s on the pump.
Table 35
Bearing LED
LED is not lit while pump is powered on No bearing condioning required
LED is ashing 0.25 s ON and 0.75 s OFF Pump has been stored for more than 12 months,
BRIM is required and will start on the next pump
start
LED is permanently ON BRIM is running
LED is ashing 0.25 s ON and 0.25 s OFF Pump has been stored for more than 3 years, bear-
ing replacement is required
12.4.1 Service counter reset
Aer compleng a bearing change, reset the service interval in order to schedule the
next service and reset the status LED. The service counter reset is described in the
manual for the service tool kit.
08/2021 - ©Edwards Limited
Page 107B8J200880_D
300812671_002_C3
B8J200880_D - Service