The output can be used to control other devices in the pumping system. The
output can driv
e a low power relay of up to 24 V d.c. coil rang (up to 20 mA).
4. To monitor the fail status output, connect the customer control equipment to the
fail output (pin 7) and to pin 2 of the customer logic interface mang half.
The output can be used to control other devices in the pumping system. The
output can drive a low power relay of up to 24 V d.c. coil rang (up to 20 mA).
Electrical supply connecon to pins 1, 6 and 11 is not required for the nEXT pump as it
has a dedicated pump power supply cable. The fuse is only required if a 48V d.c.
electrical supply is connected to the logic interface cable. Connecons to the electrical
supply via pins 1, 6 and 11 is required if indicators for either the normal speed or the
system OK status are required.
Figure 21 Logic interface connecons - par
allel control
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
15
5
3
4
2
CS/5056/A
8
48 V d.c.
V
7
6
1. Oponal 48 V d.c. electrical supply 2. Oponal fuse
3. Oponal indicat
or - normal speed 4. Oponal indicator - system OK
5. nEXT pump logic interface 6. Start switch
7. Oponal standby switch 8. Oponal voltmeter to monitor analogue
output
1. Oponal 48 V d.c. electrical supply 2. Oponal fuse
3. Oponal indicator - normal speed 4. Oponal indicator - system OK
5. nEXT pump logic interface 6. Start switch
7. Oponal standby switch 8. Oponal voltmeter to monitor analogue
output
Figure 22 Simplied logic interface connecons - parallel control
2
3
4
5
6
7
8
9
10
11
12
13
14
1
15
1
4
V
3
2
CS/5038/A
1. nEXT pump logic interface 2. Start switch
3. Oponal standby switch 4. Oponal voltmeter to monitor analogue
output
1. nEXT pump logic in
terface 2. Start switch
3. Oponal standby switch 4. Oponal voltmeter to monitor analogue
output
5.6  Connecon for serial c
ontrol and monitoring
The serial interface allows the nEXT pump to be controlled and to be interrogated as to
its operaonal status using a number of serial commands or the nST2 PC soware. There
08/2021 - ©Edwards Limited
Page 59B8J200880_D
300812671_002_C3
B8J200880_D - Installaon