2. Important safety inf
ormaon
2.1 Mechanical hazards
WARNING: EJECTION OF PARTS
If the mounng is not stur
dy enough, pump blockage could cause the pump to break
loose; internal pump components could be thrown in all direcons.
Mount the pump rmly to the vacuum chamber. Never operate the pump without
proper anging to the vacuum chamber (in bench tesng, for example). In case of
rotor destrucon a sudden twisng of the enre pump is possible. The vacuum
chamber must be able to absorb the torque of max. 5 kNm (nEXT730/930D) and 9
kNm (nEXT1230H) around the rotor's axis of rotaon in the event of sudden rotor
destrucon.
CAUTION: CUTTING AND CRUSHING
When reaching in
to open anges there is a risk of cung and crushing your ngers.
Do not operate the vacuum pump with open anges. Do not reach into the pump.
When installing the vacuum pump, rst mechanically connect the inlets and outlets
and then make the electrical connecons.
Disconnect the vacuum pump from the power supply before servicing. Only use
trained service personnel.
Before servicing, ensure that gas cannot ow through the pump. Only open the pump
system when it is under atmospheric pressure.
CAUTION: EJECTION OF PARTS
Ejecon of parts through bur
sng of vacuum system as a result of excessive pressure.
When using the pump with purge gas, protect the purge gas supply such that in the
event of a malfuncon no overpressure can occur within the system. The pressure in
the pump must not exceed 1.4 bar (absolute).
CAUTION: VACUUM
Pulling int
o the vacuum can cause injury to hands or ngers.
Do not operate the vacuum pump with open anges.
CAUTION: FALLING PARTS
Error
s during transport can cause the pump to fall down.
Transport the pump only in its transport packaging or at the eye-bolts provided for
this purpose.
08/2021 - ©Edwards Limited
Page 10B8J200880_D
300812671_002_C3
B8J200880_D - Important safety inf
ormaon

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards nEXT730D and is the answer not in the manual?

Edwards nEXT730D Specifications

General IconGeneral
BrandEdwards
ModelnEXT730D
CategoryWater Pump
LanguageEnglish

Related product manuals