Mounting procedure Proline Prosonic Flow W 400 HART
42 Endress+Hauser
Wall mounting
149 (5.85)
210.5 (8.29)
=
5.8 (0.23)
17 (0.67) =
14 (0.55)
5.8 (0.23)
A0020523
 35 Unit mm (in)
1. Drill the holes.
2. Insert wall plugs into the drilled holes.
3. Lightly screw in the securing screws.
4. Fit the transmitter housing over the securing screws and hook into place.
5. Tighten the securing screws.
Post mounting
NOTICE
Excessive tightening torque applied to the fixing screws!
Risk of damaging the plastic transmitter.
Tighten the fixing screws as per the tightening torque: 2.5 Nm (1.8 lbf ft)
ø 20…70
( 0.79…2.75)ø
~102 (~ 4.0)
4 x
SW 10
3 x
TX 25
A0029051
 36 Unit mm (in)