Electrical connection Proline Prosonic Flow W 400 HART
48 Endress+Hauser
The following sequence of steps is recommended when connecting:
1. Mount the sensor and transmitter.
2. Connect the sensor cable.
3. Connect the transmitter.
Connecting the sensor cable to the transmitter
1.
2.
4 x
T 20
UP
CH1
CH2
UP
Down
Down
5.
7.
3.
4.
6.
8.
9.
A0046768
 37 Transmitter: main electronics module with terminals
1. Loosen the 4 fixing screws on the housing cover.
2. Open the housing cover.
3. Route the two sensor cables of channel 1 through the slackened top union nut of the
cable entry. To ensure tight sealing, mount a sealing insert on the sensor cables
(push the cables through the slotted sealing insert).
4. Mount the screw part in the center cable entry at the top and then guide both sensor
cables through the entry. Then fit the coupling nut with the sealing insert on the
screw part and tighten. Ensure that the sensor cables are positioned in the cut-outs
provided in the screw part.
5. Connect sensor cable to channel 1 upstream.
6. Connect sensor cable to channel 1 downstream.
7. For a two-path measurement: proceed as per steps 3+4
8. Connect sensor cable to channel 2 upstream.
9. Connect sensor cable to channel 2 downstream.
10. Tighten the cable gland(s).
This concludes the process for connecting the sensor cable(s).
11.
L
WARNING
Housing degree of protection may be voided due to insufficient sealing of the
housing.
Screw in the screw without using any lubricant.
Reverse the removal procedure to reassemble the transmitter.