Proline Prowirl R 200 HART Commissioning
Endress+Hauser 103
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry
Factory setting
Gas mixture The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
In the Select gas type
parameter, the Gas mixture
option is selected.
Select measured gas mixture. Hydrogen H2
Helium He
Neon Ne
Argon Ar
Krypton Kr
Xenon Xe
Nitrogen N2
Oxygen O2
Chlorine Cl2
Ammonia NH3
Carbon monoxide
CO
Carbon dioxide
CO2
Sulfur dioxide SO2
Hydrogen sulfide
H2S
Hydrogen chloride
HCl
Methane CH4
Ethane C2H6
Propane C3H8
Butane C4H10
Ethylene C2H4
Vinyl Chloride
C2H3Cl
Others
Methane CH4
Mol% Ar The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
In the Select gas type
parameter, the Gas mixture
option is selected and in the
Gas mixture parameter, the
Argon Ar option is selected.
Or
In the Select gas type
parameter, the Natural gas
option is selected and in the
Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% C2H3Cl The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
In the Select gas type
parameter, the Gas mixture
option is selected.
In the Gas mixture
parameter, the Vinyl
Chloride C2H3Cl option is
selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %