Commissioning Proline Prowirl R 200 HART
104 Endress+Hauser
Parameter Prerequisite Description Selection / User
entry
Factory setting
Mol% C2H4 The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
In the Select gas type
parameter, the Gas mixture
option is selected.
In the Gas mixture
parameter, the Ethylene
C2H4 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% C2H6 The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
In the Select gas type
parameter, the Gas mixture
option is selected and in the
Gas mixture parameter, the
Ethane C2H6 option is
selected.
Or
In the Select gas type
parameter, the Natural gas
option is selected and in the
Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% C3H8 The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
In the Select gas type
parameter, the Gas mixture
option is selected and in the
Gas mixture parameter, the
Propane C3H8 option is
selected.
Or
In the Select gas type
parameter, the Natural gas
option is selected and in the
Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% CH4 The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
In the Select gas type
parameter, the Gas mixture
option is selected and in the
Gas mixture parameter, the
Methane CH4 option is
selected.
Or
In the Select gas type
parameter, the Natural gas
option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 100 %