Commissioning Proline Prowirl R 200 HART
104 Endress+Hauser
Parameter Prerequisite Description Selection / User
entry
Factory setting
Mol% C2H4 The following conditions are
met:
• In the Select medium
parameter, the Gas option is
selected.
• In the Select gas type
parameter, the Gas mixture
option is selected.
• In the Gas mixture
parameter, the Ethylene
C2H4 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% C2H6 The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
– In the Select gas type
parameter, the Gas mixture
option is selected and in the
Gas mixture parameter, the
Ethane C2H6 option is
selected.
Or
– In the Select gas type
parameter, the Natural gas
option is selected and in the
Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% C3H8 The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
– In the Select gas type
parameter, the Gas mixture
option is selected and in the
Gas mixture parameter, the
Propane C3H8 option is
selected.
Or
– In the Select gas type
parameter, the Natural gas
option is selected and in the
Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% CH4 The following conditions are
met:
In the Select medium
parameter, the Gas option is
selected.
– In the Select gas type
parameter, the Gas mixture
option is selected and in the
Gas mixture parameter, the
Methane CH4 option is
selected.
Or
– In the Select gas type
parameter, the Natural gas
option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 100 %