Commissioning Proline Prowirl R 200 HART
108 Endress+Hauser
Parameter Prerequisite Description Selection / User
entry
Factory setting
Mol% n-C4H10 The following conditions are
met:
• In the Select medium
parameter, the Gas option is
selected.
– In the Select gas type
parameter, the Gas
mixture option is selected
and in the Gas mixture
parameter, the Butane
C4H10 option is selected.
Or
– In the Select gas type
parameter, the Natural
gas option is selected and
in the Density
calculation parameter,
the ISO 12213- 2 option
is selected.
• Or
In the Select medium
parameter, the Liquid
option is selected and in the
Select liquid type
parameter, the LPG option is
selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% n-C5H12 The following conditions are
met:
• In the Select medium
parameter, the Gas option is
selected.
• In the Select gas type
parameter, the Natural gas
option is selected.
• In the Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% n-C6H14 The following conditions are
met:
• In the Select medium
parameter, the Gas option is
selected.
• In the Select gas type
parameter, the Natural gas
option is selected.
• In the Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %
Mol% n-C7H16 The following conditions are
met:
• In the Select medium
parameter, the Gas option is
selected.
• In the Select gas type
parameter, the Natural gas
option is selected.
• In the Density calculation
parameter, the ISO 12213-
2 option is selected.
Enter amount of substance for
the gas mixture.
0 to 100 % 0 %