Proline Prowirl R 200 HART Diagnostics and troubleshooting
Endress+Hauser 155
Diagnostic
number
Short text Remedy instructions Status
signal
[from the
factory]
Diagnostic
behavior
[from the
factory]
283 Memory content 1. Transfer data or reset device
2. Contact service
F Alarm
302 Device verification
active
Device verification active, please
wait.
C Warning
311 Electronic failure Maintenance required!
1. Do not perform reset
2. Contact service
M Warning
350 Pre-amplifier defective Change pre-amplifier F Alarm
1)
351 Pre-amplifier defective Change pre-amplifier F Alarm
370 Pre-amplifier defective 1. Check plug connections
2. Check cabel connection of remote
version
3. Change pre-amplifier or main
electronic module
F Alarm
371 Temperature sensor
defective
1. Check plug connections
2. Change pre-amplifier
3. Change DSC sensor
M Warning
1)
Diagnostic of configuration
410 Data transfer 1. Check connection
2. Retry data transfer
F Alarm
412 Processing download Download active, please wait C Warning
431 Trim 1 to n Carry out trim C Warning
437 Configuration
incompatible
1. Restart device
2. Contact service
F Alarm
438 Dataset 1. Check data set file
2. Check device configuration
3. Up- and download new
configuration
M Warning
441 Current output 1 to n 1. Check process
2. Check current output settings
S Warning
1)
442 Frequency output 1. Check process
2. Check frequency output settings
S Warning
1)
443 Pulse output 1. Check process
2. Check pulse output settings
S Warning
1)
444 Current input 1 1. Check process
2. Check current input settings
S Warning
1)
453 Flow override Deactivate flow override C Warning
484 Failure mode simulation Deactivate simulation C Alarm
485 Measured variable
simulation
Deactivate simulation C Warning
486 Current input 1
simulation
Deactivate simulation C Warning
491 Current output 1 to n
simulation
Deactivate simulation C Warning
492 Simulation frequency
output
Deactivate simulation frequency
output
C Warning
493 Simulation pulse output Deactivate simulation pulse output C Warning
494 Switch output
simulation
Deactivate simulation switch output C Warning