Loading...
Proline Prowirl R 200 HART Technical data
Endress+Hauser 195
Weight in US units
All values (weight) refer to devices with ASME B16.5, Class 300/Sch. 40 flanges. Weight
information in [lbs].
DN
[in]
Internal diameter
[in]
Weight [lbs]
sensor connection housing
Order code for "Housing", option J
"GT20 two-chamber, aluminum, coated,
remote"
1)
sensor connection housing
Order code for "Housing", option K
"GT18 two-chamber, 316L, remote"
1)
1R ½ 15.6 18.3
1½R 1 20.0 22.7
2R 24.4 27.2
3R 2 46.4 49.2
4R 3 66.3 69.0
6R 4 119.2 122.0
8R 6 163.3 166.0
1) For high-temperature/low-temperature version: values + 0.4 lbs
Accessories
Flow conditioner
Weight in SI units
DN
1)
[mm]
Pressure rating Weight
[kg]
15 PN 10 to 40 0.04
25 PN 10 to 40 0.1
40 PN 10 to 40 0.3
50 PN 10 to 40 0.5
80 PN 10 to 40 1.4
100 PN10 to 40 2.4
150 PN 10/16
PN 25/40
6.3
7.8
200 PN 10
PN 16/25
PN 40
11.5
12.3
15.9
250 PN 10 to 25
PN 40
25.7
27.5
1) EN (DIN)
DN
1)
[mm]
Pressure rating Weight
[kg]
15 Class 150
Class 300
0.03
0.04
25 Class 150
Class 300
0.1
40 Class 150
Class 300
0.3
50 Class 150
Class 300
0.5