Technical data Proline Prowirl R 200 HART
198 Endress+Hauser
Order code for "Housing": option C "GT20 two-chamber, aluminum, coated, compact", option J
"GT20, two-chamber, aluminum, coated remote"
Applies also to the following device versions in combination with HART
communication mode:
Order code for "Sensor version; DSC sensor; measuring tube", option DA "mass steam;
316L; 316L", option DB "mass gas/liquid; 316L; 316L"
Cable entry/cable gland Type of protection Material
Cable gland M20 × 1.5 • Non-hazardous area
• Ex ia
• Ex ic
Plastic
Adapter for cable entry with
internal thread G ½"
Nickel-plated brass
Adapter for cable entry with
internal thread NPT ½"
Non-hazardous area and hazardous
area
(except for XP)
Nickel-plated brass
Thread NPT ½"
via adapter
Non-hazardous area and hazardous
area
Connecting cable for remote version
• Standard cable: PVC cable with copper shield
• Reinforced cable: PVC cable with copper shield and additional steel wire braided jacket
Connecting cable, pressure measuring cell
The "mass" sensor version (integrated pressure/temperature measurement) is
available only for measuring devices in the HART communication mode.
Standard cable: PVC cable with copper shield
Sensor connection housing
The material of the sensor connection housing is dependent on the material selected for
the transmitter housing.
• Order code for "Housing" option J "GT20 two-chamber, aluminum, coated, remote":
Coated aluminum AlSi10Mg
• Order code for "Housing", option K "GT18 two-chamber, 316L, remote":
Stainless cast steel, 1.4408 (CF3M)
Compliant with:
– NACE MR0175
– NACE MR0103
Measuring tubes
DN 25R to 200R (1R to 8R")/DN 40S to 250S (1½S to 10S"), pressure ratings PN
10/16/25/40, Class 150/300 , as well as JIS 10K/20K:
Stainless cast steel, CF3M/1.4408
Compliant with:
– NACE MR0175
– NACE MR0103
– DN15 to 150 (½ to 6"): AD2000, permitted temperature range
–10 to +400 °C (+14 to +752 °F) restricted)
DSC sensor
Order code for "Sensor version; DSC sensor; measuring tube", option AA, BA, CA, DA, DB