Proline Prowirl R 200 HART Commissioning
Endress+Hauser 91
Parameter overview with brief description
Parameter Prerequisite Description Selection / User
entry
Factory setting
Switch output function The Switch option is selected
in the Operating mode
parameter.
Select function for switch
output.
Off
On
Diagnostic
behavior
Limit
Status
Off
Assign diagnostic behavior In the Operating mode
parameter, the Switch
option is selected.
In the Switch output
function parameter, the
Diagnostic behavior option
is selected.
Select diagnostic behavior for
switch output.
Alarm
Alarm or warning
Warning
Alarm
Assign limit The Switch option is
selected in the Operating
mode parameter parameter.
The Limit option is selected
in the Switch output
function parameter
parameter.
Select process variable for limit
function.
Volume flow
Corrected volume
flow
Mass flow
Flow velocity
Temperature
Pressure
Calculated
saturated steam
pressure
*
Total mass flow
*
Energy flow
*
Heat flow
difference
*
Reynolds number
*
Totalizer 1
Totalizer 2
Totalizer 3
Volume flow
Assign flow direction check The Switch option is
selected in the Operating
mode parameter.
The Flow direction check
option is selected in the
Switch output function
parameter.
Select process variable for flow
direction monitoring.
Off
Volume flow
Mass flow
Corrected volume
flow
Volume flow
Assign status The Switch option is
selected in the Operating
mode parameter.
The Status option is
selected in the Switch
output function parameter.
Select device status for switch
output.
Low flow cut off Low flow cut off
Switch-on value In the Operating mode
parameter, the Switch
option is selected.
In the Switch output
function parameter, the
Limit option is selected.
Enter measured value for the
switch-on point.
Signed floating-point
number
Country-specific:
0 m³/h
0 ft³/h
Switch-off value In the Operating mode
parameter, the Switch
option is selected.
In the Switch output
function parameter, the
Limit option is selected.
Enter measured value for the
switch-off point.
Signed floating-point
number
Country-specific:
0 m³/h
0 ft³/h