Commissioning Proline Prowirl R 200 HART
90 Endress+Hauser
Parameter Prerequisite Description Selection / User
entry
Factory setting
Failure frequency In the Operating mode
parameter (→  85), the
Frequency option is selected,
and one of the following
options is selected in the
Assign frequency output
parameter (→  88):
Volume flow
Corrected volume flow
Mass flow
Flow velocity
Temperature
Pressure
Calculated saturated steam
pressure
*
Total mass flow
*
Energy flow
*
Heat flow difference
*
Enter frequency output value
in alarm condition.
0.0 to 1 250.0 Hz 0.0 Hz
Invert output signal Invert the output signal. No
Yes
No
* Visibility depends on order options or device settings
Configuring the switch output
Navigation
"Setup" menu → Pulse/frequency/switch output
Pulse/frequency/switch output
Switch output function
→  91
Assign diagnostic behavior
→  91
Assign limit
→  91
Assign flow direction check
→  91
Assign status
→  91
Switch-on value
→  91
Switch-off value
→  91
Switch-on delay
→  92
Switch-off delay
→  92
Failure mode
→  92
Invert output signal
→  92