TS-10 Musician’s Manual Section 15 — Sampled Sound Parameters
17
Wave Page
The parameters on this page control all the WaveSample pointers such as sample start, sample
end, loop points, etc. Also on this page, you can choose the playback mode and set up
modulation of the sample start and/or various loop modulation options.
Note: The Wave page parameters can only be edited when the Edit Context page is set up to edit a
single WaveSample (WAVESAMPLE=###). The LAYER EDIT NOT ALLOWED message will be
displayed if you try to edit those parameters with the Edit Context set up to edit an entire layer or
an entire Sampled Sound.
Press the Wave button. The first WAVE sub-page is displayed.
PLAYBACK-MODE Range: various
This parameter allows you to select one of five possible WaveSample playback modes.
• FORWARD-NO LOOP — The TS-10 plays through the WaveSample once, from sample start
to sample end.
• BACKWARD-NO LOOP — The TS-10 plays through the WaveSample once, only in reverse,
from sample end to sample start.
• LOOP FORWARD — The TS-10 will play forward from sample start to loop end and return to
loop start and will continue playing the loop while the key is depressed. Once the key is
released the loop continues playing as the WaveSample envelopes away.
• LOOP BIDIRECTION — The TS-10 will play forward from sample start. At loop end, the TS-
10 will play the WaveSample in reverse to the loop start, playing the loop section back and
forth until the key is released.
• LOOP AND RELEASE — The TS-10 will play forward from sample start and will continue
playing the loop while the key is depressed. As soon as the key is released the TS-10 will go
into release mode from wherever it is and will keep playing until the end of the WaveSample,
playing data after the loop. LOOP AND RELEASE works in conjunction with Envelope 3,
which needs to have its MODE parameter set to FINISH, and its TIME and LEVEL values
adjusted appropriately.
SAMPLE-START
This parameter allows you to set the sample start point.
When the SAMPLE START or SAMPLE END parameters are displayed there are two ways to
adjust them — you can move in large steps by adjusting the percent setting, or move one sample
at a time by choosing the fine adjust.
Location in percent of entire wavesample (coarse adjust)
Sample Start Number (fine adjust)
The Coarse Adjust reading is the one in parentheses. Changing this value will move the Sample