C4 Maintenance 4. Cable Unit
C Series Maintenance Manual Rev.2 45
Wrap the silicone sheet around the cables as shown in the photo on
the right.
Silicone sheet: 30 mm × 150 mm
Temporarily bind the cables wrapped with the silicone sheet to the
base cable fixing plate.
Wire tie: AB150 (2 ties)
Precautions for cable unit fixation to the plate
When installing the cable unit, place the plate, the air tube, and
the cables as shown in the photo on the right (example), and
then fix the plate and the cable unit with a wire tie.
Fix the cables with the wire ties so
projects 5 mm from the base cable plate.
Pull the cable out and adjust the plate position.
Plate position: 15 mm
Fix the cable temporarily fixed by the wire tie.