Maintenance  9. Troubleshooting 
 
RC700 / RC700-A Rev.23  281 
7523 
The specified vision sequence 
already exists. 
Change the sequence name. 
Delete the existing sequence in 
   
7524 
The specified vision object already 
exists. 
Change the object name. 
Delete the existing sequence in 
   
7525  Cannot load vision project. 
The project folder may be corrupt. 
   
7526  Cannot save vision project. 
The project folder may be 
write-protect. 
Check the access permission for the 
   
7527  Vision processor.    Critical error. 
Initialize the camera. 
Rebuild the project. 
   
Check the camera connection. 
Check the camera connection. 
7533 
Camera is not supported by 
RC+7.0. 
SC300/SC1200 is not supported by 
RC+7.0. 
   
7534 
Camera firmware does not support 
new functions of RC+7.0. 
Update the camera firmware.     
Invalid data from network camera. 
7536 
Network camera export status 
Initialize the camera.     
7537 
Invalid ImageSize value. The 
specified value is not supported by 
ImageSize exceeding the camera 
resolution cannot be specified.   
Correct the property value. 
   
7538 
Invalid ZoomFactor. The specified 
value requires data outside of the 
Settable values are from 0.1 to 10.0. 
Correct the property value. 
   
7539 
The camera does not support Code 
Reader. 
Update the camera firmware.     
The camera does not support OCR. 
Update the camera firmware. 
7541  Insufficient data for teaching model. 
Black or white image cannot be 
   
7542 
Model window cannot be outside of 
image. 
Correct the position of the model 
window. 
   
7543 
Calibration points have not been 
taught. 
Teach the calibration point.     
7544  Calibration must be fixed upward. 
Sequence with the calibration data of 
the upward fixed camera is only 
   
Teach the calibration point. 
7546 
RobotPlacePos has not been 
calibrated. 
Click CalRobotPlacePos and 
calibrate RobotPlacePos. 
   
7547 
Camera IP address is out of current 
subnet. 
Correct the camera IP address.     
Check the wiring of the camera. 
7549 
Invalid Radius.    Radius must be 
>= RadiusInner and <= 
Correct the property value.     
OCR character does not exist. 
Register the OCR character. 
OCR option is not active.