Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 281
7523
The specified vision sequence
already exists.
Change the sequence name.
Delete the existing sequence in
7524
The specified vision object already
exists.
Change the object name.
Delete the existing sequence in
7525 Cannot load vision project.
The project folder may be corrupt.
7526 Cannot save vision project.
The project folder may be
write-protect.
Check the access permission for the
7527 Vision processor. Critical error.
Initialize the camera.
Rebuild the project.
Check the camera connection.
Check the camera connection.
7533
Camera is not supported by
RC+7.0.
SC300/SC1200 is not supported by
RC+7.0.
7534
Camera firmware does not support
new functions of RC+7.0.
Update the camera firmware.
Invalid data from network camera.
7536
Network camera export status
Initialize the camera.
7537
Invalid ImageSize value. The
specified value is not supported by
ImageSize exceeding the camera
resolution cannot be specified.
Correct the property value.
7538
Invalid ZoomFactor. The specified
value requires data outside of the
Settable values are from 0.1 to 10.0.
Correct the property value.
7539
The camera does not support Code
Reader.
Update the camera firmware.
The camera does not support OCR.
Update the camera firmware.
7541 Insufficient data for teaching model.
Black or white image cannot be
7542
Model window cannot be outside of
image.
Correct the position of the model
window.
7543
Calibration points have not been
taught.
Teach the calibration point.
7544 Calibration must be fixed upward.
Sequence with the calibration data of
the upward fixed camera is only
Teach the calibration point.
7546
RobotPlacePos has not been
calibrated.
Click CalRobotPlacePos and
calibrate RobotPlacePos.
7547
Camera IP address is out of current
subnet.
Correct the camera IP address.
Check the wiring of the camera.
7549
Invalid Radius. Radius must be
>= RadiusInner and <=
Correct the property value.
OCR character does not exist.
Register the OCR character.
OCR option is not active.