EasyManua.ls Logo

Epson RC700 Series - Page 295

Epson RC700 Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance 9. Troubleshooting
RC700 / RC700-A Rev.23 283
No.
Message
Remedy
Note 1
Note 2
7600
GUI Builder.
Cannot execute a GUI Builder
statement from the command
window.
-
7602
GUI Builder.
GSet parameter is too long.
Correct the parameter to the proper
length.
7603
GUI Builder.
Too many parameters for GGet.
Check the number of parameters.
7604
GUI Builder.
Not enough data for GGet statement
variable assignment.
Specify the variable.
7610
GUI Builder.
The event task cannot be executed.
System in pause state and
EventTaskType is Normal.
The system can be operated by
changing EventTaskType to
“NoPause”
7611
GUI Builder.
The event task cannot be executed.
Safeguard is open and
EventTaskType is Normal.
The system can be operated by
changing EventTaskType to
“NoEmgAbort”
7612
GUI Builder.
The event task cannot be executed.
Estop is active and EventTaskType is
not NoEmgAbort.
The system can be operated by
changing EventTaskType to
“NoEmgAbort”
7613
GUI Builder.
The event task cannot be executed.
System in error state and
EventTaskType is not NoEmgAbort.
The system can be operated by
changing EventTaskType to
“NoEmgAbort”
7650
GUI Builder.
Invalid property.
Specify the valid property.
7651
GUI Builder.
Invalid form.
Specify the valid form.
7652
GUI Builder.
Invalid control.
Specify the valid control.
7653
GUI Builder.
The specified form is already open.
Modify the program to avoid double
launch.
7654
GUI Builder.
Event function does not exist.
Check the function name set for the
event.
7655
GUI Builder.
Item does not exist.
Specify the valid item.
7656
GUI Builder.
Invalid property value.
Check the property value and
specify the valid value.
7700
Security.
Invalid user.
Contact the administrator to register
the user.
7701
Security.
Invalid password.
Check the password.
7702
Security.
Permission denied.
Contact the administrator to set
authority.
7703
Security.
Option not active.
Register the options.
7710
Source and destination cannot be the
same.
Specify another destination.
7711
Point file name is used by another
robot.
Check the point file name.