Test Setup - Test Configurator, Timer, and System
154 88000 Series
1588 PTP
Pass/Fail Verdict
Pass/Fail Verdict check box when selected (default) enables the use of the
pass/fail verdict. The global pass/fail verdict is based on the following
criteria: alarms (Link Down, Loss Sync, Loss Announce, Unusable
(G.8265.1), and/or QL Mismatch (when QL Mismatch Monitoring is
enabled)), or the test is automatically aborted (service request denied,
session canceled, or no reply for G.8265.1; sync message rate changed for
G.8275.1).
Restore 1588 PTP Defaults
Reverts the 1588 PTP test application to its default factory settings.