Test Results
554 88000 Series
Summary (FC BERT)
Summary (FC BERT)
From the Test menu, tap Results, and the Summary tab.
Test Status indicates the actual test status as follows:
“--”: The test is not running or results are not available.
In Progress: The test is running.
Completed: The test is completed, stopped at the planned time, or
manually stopped when there is no set timer.
Once the test is stopped, the test pass/fail verdict is displayed next to
the Status field when enabled. The verdict is Pass when all verdicts are
Pass, the verdict is Fail as soon as one of the verdict is Fail. Refer to
Bit/Pattern Error on page 185 and Latency Tag Insertion on page 187 for
more information.
Start Time indicates the date and time the test was started. The date
and time is reset every time the test is restarted or reset.
Test Recover y, when displayed, indicates that the test has
automatically recovered from a power failure. The number of
occurrences is also displayed next to the Test Recover y field. Refer to
Power Failure Recovery on page 743.
Logger Full, when displayed, indicates that the logger is full. Refer to
Logger on page 493.