Test Setup - Test Configurator, Timer, and System
238 88000 Series
Labels
Labels
For SONET/SDH BERT: From the Test menu, tap Setup, Test Configurator,
the interface block, and on the Labels tab.
For OTN-SONET/SDH BERT: From the Test menu, tap Setup, Test
Configurator, the protocol block, and on the Labels tab.
Note: Selecting a Label byte to be generated will automatically update the
corresponding OH byte. Refer to OH - SONET/SDH on page 666 for more
information.
Labels
STS/AU Path (C2): The C2 byte is allocated to indicate the content of
the STS SPE / VC, including the status of the mapped payloads.
Generated: Select the C2 byte from the list. Selecting a C2 byte value
will automatically update the OH C2 selection and vice versa. Refer to
C2 on page 674 for more information.
PLM-P/UNEQ-P / HP-PLM/HP-UNEQ: Enables the Payload Mismatch
and STS/AU UNEQ monitoring. This setting is coupled with the
configuration of Traces (SONET/SDH) on page 597.
Expected: Select the expected C2 byte from the list. Refer to C2 on
page 674 for more information.