Test Setup - Test Configurator, Timer, and System
Power Blazer 223
Interface
Interface
From the Test menu, tap Setup, Test Configurator, the interface block,
and the Interface tab.
Port, FlexO Instance ID, and FlexE PHY Number
Note: Only available with FlexE/FlexO BERT test application.
Port allows selecting the physical port to be displayed.
FlexO Instance ID indicates and allows changing the FlexO Instance
ID (1 to 254) assigned to the port.
FlexE PHY Number indicates and allows changing the FlexE PHY
number (1 to 254) assigned to the port.
LINK
An arrow is used to indicate the port link status (at the PCS level for parallel
interfaces): link up (green arrow), error or link down (red arrow), or
awaiting incoming data to provide a status (gray arrow).
Note: Refer to Ethernet on page 405, Fibre Channel on page 413, Ethernet - PCS
on page 408, and PHY on page 448 for more information on alarms.
For 25GE framed Ethernet interface:
RS-FEC check box when selected (default) enables the use of RS-FEC.
For 100GE (4 Lanes) framed Ethernet interface:
RS-FEC check box when selected (default), enables the use of the
RS-FEC; ensure both ends of the circuit have the FEC enabled. The
RS-FEC check box should be selected when using a 100GBASE-SR4,
100G-CWDM4, or 100G AOC transceiver but may be cleared for testing
purposes. Not available when the PHY Type is set to LR4/ER4 (see
page 132).