Test Results
Power Blazer 479
Analysis - Time Error / Time Interval Error
Analysis - Time Error / Time Interval Error
From the Test menu, tap Results, Analysis, and the Time Error /
Time Interval Error tab.
Graph
Graphically displays the time error values as a function of time.
Note: A refresh is required to update the graph (see Refresh below).
Note: It is possible to zoom/un-zoom on time error (Y axis):
Using the touch screen, use the pinch-to-zoom to zoom/un-zoom.
Using a mouse, click and drag (highest to lowest value to zoom and lowest
to highest value to un-zoom).
Offset
Remove Offset check box when selected, displays a second TE/TIE
trace on which the frequency offset has been removed.
Freq. Offset (ppm) indicates an estimated frequency offset of the
signal under test since the beginning of the test.
Zoom
Allows zooming to a desired time region (X axis).
Time (Start/End) allows selecting the starting and ending time for the
zoom.
Display full range on Test Stop check box when selected (default)
displays the full test duration on the Time axis when the test stops.
Refresh
Refreshes the page with the latest setting and collected data.