Test Setup - Test Configurator, Timer, and System
Power Blazer 291
RFC 2544 - Global
RFC 2544 - Global
From the Test menu, tap Setup, Test Configurator, tap on the RFC 2544
block, and on the Global tab.
Dual Test Set
Dual Test Set (DTS) check box when selected (cleared by default)
enables RFC 2544 Dual Test Set. Once Dual Test Set is enabled, use
the Discover Remote button to select a remote unit. Not available in
Dual Port topology.
Note: It is also possible using the Discover Remote button to connect to a remote
module and automatically enable Dual Test Set. For more details, refer to
Discover Remote Button on page 718.
Disconnected indicates that there is no connection established
with a remote module.
Connected indicates that the connection is established with a
remote module.
Discover Remote button allows discovering remote module
supporting Remote Loopback and/or Dual Test Set. For more details,
refer to Discover Remote Button on page 718.
Global Options
Flow Direction allows the selection of the traffic direction as follows:
TX to RX for Single Port topology.
Port #1 to Port P2, Port #2 to Port #1, and Bidirectional for
Dual Port topology.
Local to Remote, Remote to Local, and Bidirectional for Dual
Test Set.