Test Setup - Test Configurator, Timer, and System
Power Blazer 279
ODU Channels - Global
ODU Channels - Global
From the Test menu, tap Setup, Test Configurator, tap on the test block
(ODU Channels), and on the Global tab.
Note: The ODU channels global configuration applies to all channels.
Pattern
The test pattern icon next to the Pattern label indicates the status of the
received pattern signal. Refer to Status Bar on page 32 for more
information.
No Pattern Analysis (Live) check box when cleared (default),
monitors the received traffic pattern. For live traffic, the No Pattern
Analysis (Live) check box should be selected as the traffic is a live
pattern thus there is no analysis of pattern loss and bit error.
Pattern sets the test pattern that will be generated: PRBS31 (default)
or NULL Client (0000).
Invert check box, when selected (cleared by default), inverts the test
pattern meaning that every 0 will be changed for 1 and every 1 for 0.
For example, the pattern 1100 will be sent as 0011.