Test Results
Power Blazer 413
Alarms/Errors Overview
FEC (OTN)
Error
FEC-CORR-CW/SYM/BIT (FEC Correctable Codeword/Symbol/Bit)
RX: FEC Codeword/Symbol/Bit that contains errors and were
corrected.
FEC-UNCORR-CW/SYM/BIT (FEC Uncorrectable
Codeword/Symbol/Bit)
RX: FEC Codeword/Symbol/Bit that contains errors and were not
corrected.
Fibre Channel
Alarms
Link Down
RX: The Fibre Channel connection is down meaning that there is a
local or a remote fault condition.
Local Fault Detected (FC 10X)
RX: Indicates that at least one of the following events is detected: LOS,
Loss of bit synchronization, Loss of Block synchronization, Link
down, or High BER (High BER is true when the bit error ratio > 10
-4
on
a fixed 125 μs time period).
Local Fault Received (FC 10X)
RX: Indicates that the received data path contains the Local Fault
signal.
Remote Fault (FC 10X)
RX: Indicates that a Remote Fault event is detected.
LOCWS (FC 32X)
RX: Indicates that the codeword_sync is false.