Test Setup - Test Configurator, Timer, and System
302 88000 Series
RFC 2544 - Subtests
Frame Loss Threshold (%) sets the threshold
1
value of frame loss for
all frame sizes when applicable.
Latency Threshold / Round-Trip Latency Threshold sets the
threshold value as the maximum delay in ms or μs for all frame sizes
when applicable. For Dual Test Set, only available with Round-Trip
Latency Measurement Mode (see Latency Configuration on
page 299).
One-Way Latency Threshold, available for Dual Test Set with
One-Way Latency Measurement Mode (see Latency Configuration on
page 299), sets the maximum one-way latency value in millisecond,
allowed for all frame sizes.
Latency Unit allows selecting either ms or μs as the reference unit for
the Latency Threshold.
1. The verdict is PASS when the received/measured value is lower or equal to the threshold value.