304 88000 Series
RFC 6349
Discover Remote button, available with Dual Test Set, allows
discovering remote modules supporting Dual Test Set. For more
details, refer to Discover Remote Button on page 718.
Direction allows the selection of the traffic direction: Local to Remote,
Remote to Local, and Bidirectional (default).
Remote IP Address, available with EXFO|Worx Interop, is either the
remote IP address of the verifier or the WAN IP address when the
verifier is behind a NAT router.
TCP Port is the port used by the server located at the remote side: 1 to
65535 (excluding 62819 that is used for DTS connection), default is
50201. The port forwarding rule for the defined TCP port must be
created on the NAT router when the remote is behind a NAT.
Parameters
Multiple Connections check box when selected (default) indicates
that the applicable TCP Throughput phases are performed with
multiple connections; otherwise TCP Throughput phases are
performed within a single connection. For 40/100GE rate, this check
box is selected and the Window Size Target per Connection can be
used to set the target window.
Window Size Target per Connection, available for 40/100GE rate,
selects the target window per connection: 1MiB, 4MiB, 8MiB, 16MiB
(default), and 32 MiB.
CIR
The Local-to-Remote CIR and Remote-to-Local CIR represent the
Committed Information Rate of the Ethernet Service under test:
1.0 Mbit/s to Line Rate. The CIR is not used to actually transmit frames
at this rate but to calculate a Bandwidth Delay Product (BDP) which in
turn is used to set the Max Window Size of the TCP connections.
Rate Unit determines the unit used to display the rate values:
Mbit/s (default) or Gbit/s.