EasyManua.ls Logo

EXFO Power Blazer - Page 385

EXFO Power Blazer
887 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Setup - Test Configurator, Timer, and System
Power Blazer 375
Traces (SONET/SDH)
Note: 16-bytes selection allows typing up to 15 bytes (a CRC-7 byte will be added
in front for a total of 16 bytes). 64-bytes selection allows typing up to
62-bytes (<C
R
> and <L
F
> bytes will be added at the end for a total of
64-bytes). Traces values should be ASCII suitable characters including the
ITU T.50 Characters on page 46.
TIM-S/RS-TIM, TIM-P/HP-TIM, TIM-V/LP-TIM: Enables the
corresponding Trace Identifier Mismatch for the expected message
defined. These settings are coupled with the Result - Traces/Labels
configuration (refer to Traces (SONET/SDH) on page 597).
Format: Allows the selection of the expected format:
16 Bytes (default), or 64 Bytes.
Expected: Allows entering the expected J0 trace message for
TIM-S/RS-TIM, J1 for TIM-P/HP-TIM, and J2 for TIM-V/LP-TIM. See
Default values/messages on page 374.
TCM Access Point Identifier
Note: Available when TCM is enabled from the Signal - Signal Configuration
(SONET/SDH) on page 345.
STS/AU Path (N1), and VT/TU Path (Z6 or N1 (TU-3))
Enter the N1/Z6 value/message to be generated.
TC-TIM-P/HPTC-TIM/TC-TIM-V/LPTC-TIM: Enables the corresponding
TCM Access Point Identifier for the expected message defined. These
settings are coupled with the Traces configuration from Traces
(SONET/SDH) on page 597.

Table of Contents