Test Results
494 88000 Series
Logger
Save to CSV
Allows saving the logger content to a CSV file format.
Table
The logger table provides the following event logger information.
ID: Indicates the event identification number. The events are
sequentially numbered.
Start Time: Indicates when the event has been started or detected.
Event: Provides the event type and threshold crossing information.
Duration or End Time, depending on the Closure Format selected,
indicates either the duration or at what time the event has been
completed or cleared.
Details: Provides contextual information including the pass/fail verdict.
The following table displays the nature of information reported by type of
event:
Note: The Logger table can display up to 5000 event entries. Once the Logger
table reports 5000 event entries, a log full indicator appears and no further
entries are possible. However, the events in the Pending state will be
updated if the test is still running.
Type of Event Nature of Information
Test Started Start Date
Test Stopped Pass/Fail Verdict
Alarm Events Count value
Error Events Current Count and Total Count
SDT Events Service Disruption Time
Threshold Crossing Event Value at the end of the test