Test Results
Power Blazer 565
Summary (iSAM)
RFC 6349 Test
Test Status indicates the actual test status as follows:
MTU (bytes) is the validated Maximum Transfer Unit.
Minimum RTT (ms) is the minimum time between the first bit of a
segment sent and the last bit of the corresponding acknowledge.
TCP Throughput
Service indicates the service’s number and name. The pass/fail
verdict icon is displayed next to the service name. A fail verdict is
declared if any of the following conditions occurs: Link Down,
LOS, TCP Throughput verdict failed, or an abort condition
(Timeout, DTS connection lost, unresolved address, user stopped,
configuration synchronization error, invalid MTU).
L->R and R->L indicates respectively the direction from local to
remote and remote to local.
Test Status Description
“--” Test has not started.
In Progress The test is running.
Completed, <Verdict> Test has completed and the test pass/fail verdict is displayed
when enabled. A fail verdict is declared if any of the following
conditions occurs: Link Down, LOS, TCP Throughput verdict
failed, or an abort condition (Timeout, DTS connection lost,
unresolved address, user stopped, configuration
synchronization error, invalid MTU).
Aborted, <reason> Test has been aborted either manually (Stop) or automatically
from an alarm and the reason is displayed as follows:
Link down alarm, LOS alarm, Timeout during execution,
DTS connection failed, Invalid Configuration,
Unresolved addresses, Invalid MTU, User Stopped,
TCP Timeout, TCP Connection failed, NAT detection failed,
Missing DTS-NAT SW option