Test Results
582 88000 Series
Summary (S-OAM and MPLS-TP OAM)
RX Line Utilization meter and value, available with Loopback
function, indicate the line rate utilization percentage (only LBR frames
are considered) received in the last second.
TST RX Rate meter and value, available with Test function, indicate the
quantity of TST frames received in the last second.
Frame Delay meter and value, available with Frame Delay function,
indicate the average of the measured frame delays in the last second.
Frame Loss Ratio meter, available with Frame Loss function,
indicates for both Near-End and Far-End the last measured frame loss
ratio in the last second.
Synthetic Loss Ratio meter, available with Synthetic Loss function
which is available with Ethernet OAM, indicates for both Near-End and
Far-End the last measured Synthetic Loss ratio in the last second.
Note: Refer to S-OAM and MPLS-TP OAM on page 514 for more
alarms/errors/statistics information.
Summary
Refer to S-OAM and MPLS-TP OAM on page 514 for more information on
alarms.
Thresholds
Refer to Thresholds on page 308 for more information.