Test Functions
Power Blazer 615
40/100/200/400G Advanced - CFP4/CFP8/OSFP/QSFP+/QSFP28/QSFP56-DD Control
CFP4/CFP8/OSFP/QSFP+/QSFP28/QSFP56-DD Control
Pins
Allows the following transceiver control pin settings. Refer to the CFP MSA
standard for more information.
Note: To apply any control, first select its check box then clear it; the control is
applied only when the selected check box is cleared.
TX Disable
1
check box (cleared by default).
Module Low Power Mode
2
check box (cleared by default).
Module Reset check box (cleared by default).
Module Power Shutdown check box (cleared by default).
CFP4/CFP8/OSFP/QSFP+/QSFP28/QSFP56-DD Status
Pins
Gives the following transceiver’s pin status (refer to the CFP/QSFP MSA
standard for more information):
1. Not supported with OSFP/QSFP+/QSFP28/QSFP56/QSFP56-DD.
2. Not supported with QSFP56-DD.
Transceiver Pin status
CFP4
CFP8
Module Absent, RX Loss of Signal, Global Alarm
OSFP
QSFP+/
QSFP28/
QSFP56-DD/
QSFP56
Module Absent