Test Functions
622 88000 Series
40/100/200/400G Advanced - Lanes Mapping & Skew
Laser ON/OFF
Allows activating the laser control per optical lane or for all lanes.
Optical lane numbers are from 0 to 3 or 0 to 7 depending on the
selected interface/rate.
All Lanes check box, when selected, applies the change(s) to all
optical lanes at once.
Optical Lane indicates the optical lane numbers and All which
represents the setting for all optical lanes when the All Lanes
check box is selected.
Laser check box, when selected, indicates that the corresponding
optical laser lane is activated and emitting an optical laser signal.
Skew Alarm Threshold (bits)
Allows setting the threshold value that will be used to declare a skew alarm
(see Ex. Skew on page 440).
Default button restores the default alarm threshold value.