Chapter 3 Cutting Function
28
3.12.6 Crash / Position Successful Signal Check
In the non plasma cutting status, punch occurs to crash and crashing signal or
location successful signal is available, torch automatically ascending time is
location up time. Refer to location up time in the figure 7.4.
In the plasma cutting status, punch occurs to crash and crashing signal or
location successful signal is available, it will automatically stop and the
torch will automatically ascend, the time of which is the torch ascend time.
Refer to torch ascend time in the figure 7.4.
In the process of ascending, pressSTOPor torch up and down body touch
with the upper limit status, it will stop ascending.