F1 Common F2 Flame F3 Plasma F5 System F6 Import F7 Export F8 Save
Horizontal Axis Pulse 125.000 n/mm
Vertical Axis Pulse 125.000 n/mm
Max cutting speed 2000.000 mmpm
Max G00 speed 6000.000 mmpm
Max Manual speed 3000.000 mmpm
Small arc limit 500.000 mmpm
Limit speed below radius 0.00 mm
Flame adjust time 0.40 s
Plasma adjust time 0.30 s
Emergency stop time 0.08 s
Start speed 250.000 mm
Max +X 100000.000 mm
Max +Y 100000.000 mm
Min -X -100000.000 mm
Min -Y -100000.000 mm
F4 Powder
Sure to export Parameter?
Fig.7.8 Parameter export
7.8 Save Parameters
After parameter modification, press F8 to save, shown in Figure 7.9.
F1 Common F2 Flame F3 Plasma F5 System F6 Import F7 Export F8 SaveF4 Powder
Parameter saved successfully
Fig.7.9 System Parameters
Notewhen any parameter has been modifiedyou must take preservation operation
to keep modification valid, or the system will take the original parameters.