Chapter 7 Parameter Setting
59
when the motor is up to the cutting speed.
Emergency STOP Time: When encounter Emergency Stop input, the time for
dropped from the current speed to zero.
Start Speed: the systems speed when it began to start. Generally do not have to start
from 0 , motor will allow a start speed.
Max Coordinate: The maximum positive coordinate which the machine can reach
horizontally. Its unit is mm (millimeter). If current coordinate exceeds the value, the
system will stop running.
Min Coordinate: The minimum negative coordinate which the machine can reach
horizontally. Its unit is mm (millimeter). If current coordinate is less than the value,
the system will stop running
7.6 Parameter Import
In the parameter configuration interface, press F6 to import the parameters. The
parameters should satisfy two conditions:
1. The parameters exported from the incising machine control system( refer to 7.7
Parameter Export) should satisfy the specified format. The file format is F2300.DAT
2. The file should be stored under the root folder of flash disk which is connected to
the USB interface.
When the above condition is satisfied, in the Fig 7.7, press Enter to confirm, and then
you could import the backup parameters to the system.