Chapter 7 Parameter Setting
52
F1 Common F2 Flame F3 Plasma F5 System F6 Import F7 Export F8 Save
Ignition time 0.00 s
Low preheat time 10.00 s
High preheat time 0.00 s
Pierce 1 time 0.00 s
Pierce 2 time 0.00 s
Pierce 3 time 0.10 s
Blow time 0.00 s
Torch up time 0.00 s
Torch down time 0.00 s
Pierce up time 0.00 s
Pierce down time 0.00 s
THC enable No <->
Hold preheat Yes <->
Edge cutting enable No <->
F4 Power
Fig 7.2 Flame Parameters
Ignition Time: the time delay of opening ignition I/O.
Low Preheat Time: The preheating time before perforating the steel plate. Enter any
positive number, unit is s. During the low pressure preheating process, you can
prolong the preheating time by pressing “stop” key, then the preheating time will
delay until you press the “start” key to start to high pressure preheat delay.
High Preheat Time: Like Low Preheat Time except open different IO.
Pierce 1 Time: Perforation time with low pressure fuel gas. Enter any positive
number, unit is s.
Pierce 2 Time: Perforation time with middle pressure fuel gas. Enter any positive
number, unit is s.
Pierce 3 Time: Perforation time with high pressure fuel gas. Enter any positive
number, unit is s.
Exhaust Time: The delay of turned off oxygen gas to open the exhaust. Enter any
positive number, unit is s.
Torch Up Time: When oxygen gas is turned off, the time for the torch to lift up. Enter
any positive number, unit is s.
Torch Down Time: When oxygen gas is turned off, the time for the torch to put down.
Enter any positive number, unit is s.