ST100A Series Flow Meter INSTALLATION
Fluid Components International LLC 17
Integral Electronics
The integral electronics package is mounted during the flow element installation process. The integral electronics can be rotated ±180
degrees on the top of the flow element insertion pipe. This is done by loosening the lock nut at the base of the enclosure and rotating the
enclosure to the preferred orientation. Do not rotate the electronics enclosure more than ±180 degrees. Damage to internal wiring
may result from over-rotating the enclosure.
Lock Nut Torque Specification: 30-35 ft-lbs (40-47 N-m)
Provide integral electronics with additional support/bracing in applications where excessive vibration is present. A mounting bracket is
available from FCI to support the electronics when additional support is required. See Figure 10 below.
Figure 10Integral Electronics Installation (Compression Fitting Shown)