OPERATION ST100A Series Flow Meter
42 Fluid Components International LLC
Click Get from Device. This displays the current date and the ST100A Series system time. If needed, set the correct date using the field's calendar
date picker and time using the field's spinner buttons. Click Send to Device to save the changes to the instrument.
Totalizer Setup
The flow totalizer function accumulates the instrument total flow, much like the odometer on an automobile. The engineering flow units must be set in
mass or volumetric units for the function to work. The totalized flow value is displayed directly below the indicated flow rate on the instrument display.
The totalizer is enabled and displayed by default. Use the ST100A Series configuration software to set up the totalizer. The totalizer cannot be
programmed using the HMI menu interface.
Figure 42 – Example Totalizer Display Showing Total Flow Value
Start the ST100A Series confi
guration software application. Click USB Connect on the home screen. Select the Basic Setup branch from the menu
tree on the window's left side. Select the Totalizer tab. Configure as desired (check/uncheck the checkboxes). Click Send to Device to save the
changes to the instrument (enter the user level password 2772 when prompted). Click Get from Device to verify any changes.
Figure 43 – Totalizer Setup Screen
Flow Value