Installing and Connecting the Camera
CM-3202-11-I Installation and User Guide Revision 100
June 2020
12
This document does not contain any export-controlled information.
Installing and Connecting the Camera
This chapter describes how to install and connect the unit. It includes the following topics:
Pre-Installation Checklist
Outdoor Mounting Recommendations
Mounting Instructions
Powering the Camera
Connecting the Camera to the Network
Resetting the Camera
Change the Video Format (Optional)
3.1 Pre-Installation Checklist
Before installing the unit, make sure that:
Instructions in the General Cautions and Warnings and Site Preparation
sections are followed.
All related equipment is powered off during the installation.
Use best security practices to design and maintain secured camera access, communications
infrastructure, tamper-proof outdoor boxes, etc.
All electrical work must be performed in accordance with local regulatory requirements.
Caution
To avoid damage from overheating or unit failure, assure that there is sufficient temperature
regulation to support the unit’s requirements (cooling/heating). Operating temperature should be kept
in the range -30°C to 60°C (-22°F to 140°F), with no more than 90% non-condensing humidity.
Attention
Afin d'éviter tout dommage dû à une surchauffe ou toute panne de l'unité, assurez-vous que la
régulation de température est suffisante pour répondre aux exigences de l'unité
(refroidissement/chauffage). La température de fonctionnement doit être maintenue dans la plage (-
30° à 60°C/-22° à 140°F), sans condensation d'humidité supérieur à 90%.
3.2 Outdoor Mounting Recommendations
Following are additional considerations for outdoor installation:
For outside wiring installation, always use weatherproof equipment, such as boxes, receptacles,
connectors, etc.
For electrical wiring, use the properly rated sheathed cables for conditions to which the cable will be
exposed (for example, moisture, heat, UV, physical requirements, etc.).
Plan ahead to determine where to install infrastructure weatherproof equipment. Whenever possible,
ground components to an outdoor ground.