Installing and Connecting the Camera
CM-3202-11-I Installation and User Guide Revision 100
June 2020
15
This document does not contain any export-controlled information.
Figure 12: Adjusting the Camera Position
Caution
Note the limits for the three adjustment axes:
Pan adjustment range : >360°
Horizontal rotation range : ±175°
Tilt adjustment range : 27° 90°
Place the desiccant in the camera.
a. Carefully tear open the vacuum-packed aluminum desiccant bag along the slit on one edge.
b. Remove the desiccant.
c. Remove the paper backing of the double-sided tape on one side of the desiccant.
d. Firmly attach the desiccant to the camera in the location shown.
Figure 13: Desiccant Location
Caution
After placing the desiccant in the camera, attach the camera cover as soon as possible.
To prevent condensation in the camera, tightly seal the mounts and conduits. Otherwise,
the desiccant will become damp and cannot be used.