Operation
CM-3202-11-I Installation and User Guide Revision 100
June 2020
35
This document does not contain any export-controlled information.
To configure the alarm output pin state
Figure 35: Alarm Output Pin - Pulse Settings
1. Click Output.
2. Click Alarm.
3. Select whether the display state of the alarm output pin is On or Off.
4. Select the state in which the alarm output pin is not alarmed: Open (default) or Closed.
5. Select the method of alarm output pin activation:
Pulse: Activates the alarm output pin for a configurable duration (On Time, between 0.1-200
seconds), interval (Off Time, between 0.1-200 seconds), and Count (between 1-Infinite
Frame).
Normal: Activates the alarm output pin for a single configurable Duration (5, 10, 15, 30
seconds) or an Infinite duration.
Figure 36: Alarm Output Pin - Normal Settings
If you made any changes on the I/O page, click Save to apply the changes. Click Reset to discard
changes and revert to the last saved settings.
4.6 Illumination Page
The Illumination page enables you to activate and configure the camera’s infrared (IR) LED illumination.