Item Description
11 Vessel symbol your vessel's current
position.
12 Data overlay used to display data such as
depth on the chart screen.
13 Range out use icon to range out
(Touchscreen displays only).
14
Range in use icon to range in (Touchscreen
displays only).
Manipulating the 3D chart view
From the chart application:
1. With the chart in 3D mode, go to the Adjust
Viewing Angle menu: Menu > Adjust Viewing
Angle.
2. Select Adjust: so that Pitch and rotate is
highlighted.
3. To adjust the pitch:
i. Non-touchscreen or HybridTouch displays
Move the Joystick Up or Down to adjust the
pitch
ii. HybridTouch or Touch only displays Swipe
your nger up or down across the screen to
adjust the pitch.
4. To adjust the rotation:
i. Non-touchscreen or HybridTouch displays
Move the Joystick Left or Right to adjust the
rotation
ii. HybridTouch or Touch only displays Swipe
your nger left or right across the screen to
adjust the rotation.
3D Display Options
The following options are available with the Chart
application in 3D view:
Center Of View Switches a cross hair on and
off at the center of the screen at sea level.
Exaggeration Adjusting the exaggeration has
the effect of vertically stretching objects on the
chart, making it easier to see their shape and
position.
Transducer Cone Switches on and off a cone
symbol which indicates the coverage of your sonar
transducer.
Depth Scale Switches on and off a depth scale
at your vessel position.
Enabling center of view
In 3D view, to enable the center of view cross hair at
sea level follow the steps below.
From the Chart application menu:
1. Select Presentation.
2. Select View & Motion.
3. Select 3D Display Options.
4. Select Center of View so that On is highlighted.
Selecting centre of view will switch the cross hair
on and off.
Adjusting the 3D exaggeration
In the 3D chart view.
From the Chart application menu:
1. Select Presentation.
2. Select View & Motion.
3. Select 3D Display Options.
4. Select Exaggeration:.
The Exaggeration numeric adjust control is
displayed.
5. Adjust the numeric adjust control to the required
setting, between 1.0 and 20.0
6. Select OK or Back to conrm the setting and
close the numeric adjust control.
Enabling transducer cone
In 3D view, to enable the transducer cone which
indicates the coverage of your Sonar transducer
follow the steps below.
From the Chart application menu:
1. Select Presentation.
2. Select View & Motion.
3. Select 3D Display Options.
4. Select Transducer Cone so that On is
highlighted.
Selecting Transducer cone will switch the function
on and off.
Enabling depth scale
In 3D view, to enable a depth indicator at your
vessel’s location follow the steps below.
From the Chart application menu:
1. Select Presentation.
2. Select View & Motion.
3. Select 3D Display Options.
4. Select Depth Scale: so that On is highlighted.
Selecting depth scale will switch depth indicator
on and off.