EasyManuals Logo

Foif RTS680 Series User Manual

Foif RTS680 Series
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
50
11. REM
REM is a function used to measure the coordinate and height to a point where a target
cannot be directly installed such as power lines, overhead cables or bridges, etc.
Here is the equation used to calculate the data presented in above figure:
Ht=H1+Scosα1tgα2-Ssinα1
Procedure of REM
1. Set a target directly under or directly over the object
and measure the target height with a tape measure etc.
2. Press F2: [
MENU] on P2 of the basic measurement
mode, then select “
6.REM” on P1 to enter into REM
status.
3. Reference point measurement.
Aim at the prism accurately, and press F4: [
MEAS] to
measure distance. Press F4: [
STOP] and the measured
data are displayed. Press F4: [
MEAS] to re-measure.
4. Aim at the target accurately and press F2: [
REM].
The height from ground to the target is displayed in
Ht”. Press F4: [MEAS] to repeat and press key {ESC}
back to menu mode.
α1
Ht
H2
H1
B’
S
Target point B
α2
REM
Need prism obs
SD
HD
VD
I
REM MEAS
REM
Ht. 1.518ft
SD 33.421ft
HD 0.000ft
VD 15.790ft
I
REM MEAS
Menu P1
1.Coordinate
2.Stake out
3.Area
4.Offset
5.MLM
6.REM
7.Resection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Foif RTS680 Series and is the answer not in the manual?

Foif RTS680 Series Specifications

General IconGeneral
BrandFoif
ModelRTS680 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals