38
4. Input the coordinates of the stake out point.
Press F1: [
READ] to read the existed coordinates as
stake out coordinate.
Press F4: [
OK] to set the data.
5. Press F1: [
MEAS] begin coordinate stake out
measurement. Move the prism to find the point to be
stake out.
: Move the prism upward
: Move the prism downward
Press key {
ESC} back to stake out mode.
7.3 REM Stake out Measurement
Perform this operation to find a point where a target cannot be directly installed, see “§
11 REM”.
【Procedure of REM stake out measurement】
1. Set a target directly below or directly above the
point to be found, then use a measuring tape etc. to
measure the target height (height from the surveying
point to the target).
Press F1: [
MENU] at P2 in the measure mode, then
select “
2. Stake out”.
2. Select “
1. Occ. Orientation”.
Input the occupied orientation data, see “§6.1
Input the occupied point data ”.
3. Select “
2. S-O data”, then select “1. Height”.
4. Input height from the surveying point to the
position to be stake out. Then press F4: [
OK] to set the
data.
S-O Coord
Np: 157.000
Ep: 0.178
Zp: 0.000
Pt#
Tgt.H 1.500m
READ REC MOKS
↓ -147.328m
0.000m
19.310m
S-O dHD ↑ -147.328
S-O dHA→ 146.7194go
VA 296.1184gon I
HA 249.0324gon
MEAS NEXT MOKS
S-O
1. Occ. Orientation
2. S-O data
3. EDM
S-O Ht
Ht. 2.000m
Tgt.H 0.000m
MOKS
Stake out
1.Height
2.Angle & Dist
3.Coord