37
Press F1: [MEAS] to start distance measurement.
7. The difference of measured and stake out
value ”
S-O dSD” is displayed.
Move the prism forward and backward until “S-O
dSD” is 0m.
: Move the prism left
: Move the prism right
: Move the prism forward
: Move the prism backward
Press F4: [OK] back to stake out mode.
7.2 Coordinates Stake out Measurement
After setting coordinates for the point to be stake out, the instrument calculates the stake
out HA and HD. By selecting the HA and then the HD stake out functions, the required
coordinate location can be stake out.
To get the Z coordinate, attach the target to a pole etc, with the same target height.
Procedure of coordinate stake out measurement
1. Press F1: [
MENU] at P2 in the measure mode.
Select
2. Stake out”.
2. Select “
1. Occ. Orientation”.
Input the occupied orientation data, see “§6.1
Input the occupied point data ”.
Then set the azimuth angle of the backsight point,
see “§6.2 Azimuth setting”.
3. Select “
2. S-O data”, then select “3.Coord”.
S-O dSD 5.251m
S-O dHA 82.5440gon
SD
VD 149.3610gon
HA 334.9916gon I
MEAS MOKS
Point to be
stake out
Back sight
station
Instrument
station
Distanc
Angle
0
E
N
S-O
1. Occ. Orientation
2. S-O data
3. EDM
Menu P1
1.Coordinate
2.Stake out
3.Area
4.Offset
5.MLM
6.REM
7.Resection
Stake out
1.Height
2.Angle & Dist
3.Coord

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Foif RTS680 Series and is the answer not in the manual?

Foif RTS680 Series Specifications

General IconGeneral
BrandFoif
ModelRTS680 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals