Maintenance and care
147
16.10 Sealer (optional)
16.10.1 Cleaning
The sealer should be cleaned once a month to remove glue residues.
Separate the sealer from the postage
meter:
Slightly lift the postage meter on the left
side and pull the sealer away to the left.
Swing up the rocker with the moistening
felt.
Thoroughly rinse absorption and
moistening felts under running water.
Wipe the housing with a damp cloth. You
can also use a commercially available
dishwashing detergent.
Fill with sealing liquid (see page 148).
Dry the sealer.
Connect the sealer to the postage meter
(see page 22).
Rocker with
moistening felt
Moistening felt
Absorption
felt

Table of Contents